A SOGI Based Band Stop Filter Approach for a Single-Phase Shunt Active Power Filter
Özet
Control of shunt active power filter (SAPF) requires a cascaded control structure as inner current closed loop followed by outer voltage control loop. The inner current control loop is responsible for tracking of a reference current while the outer voltage loop regulates DC bus voltage to a fixed value. Dynamic performance of the DC bus voltage regulation suffers from the adverse effects such that harmonic currents produced by SAPFs lead to fluctuations in DC bus voltage at certain harmonic frequencies. This causes SAPF to produce additional harmonic components, since the outer voltage loop deals with only fundamental waves where the fluctuations should not appear. This study proposes a DC bus voltage regulation methodology based on a Second Order Generalized Integrator (SOGI) acting as a band-stop filter with the aim of increasing the voltage regulation performance in the steady state. The proposed filter does not affect the transient response thanks to that it only suppresses the harmonic-induced fluctuations in DC bus voltage. Through a simulation study, the proposed methodology is validated, and the results prove the performance and feasibility of the proposed filter. © 2018 IEEE.
Kaynak
ISMSIT 2018 - 2nd International Symposium on Multidisciplinary Studies and Innovative Technologies, ProceedingsKoleksiyonlar
İlgili Öğeler
Başlık, yazar, küratör ve konuya göre gösterilen ilgili öğeler.
-
An Improved Harmonic Extraction Method for Grid Interactive Power Electronic Systems
Kuyumcu, Ali; Karabacak, Murat (Institute of Electrical and Electronics Engineers Inc., 2020)Nonlinear and unbalanced loads causing harmonic currents to be drawn from microgrid give rise to unbalanced and distorted voltages at the Point of Common Coupling (PCC). In order to provide acceptable PCC voltages under ... -
A SOGI Based Band Stop Filter Approach for a Single-Phase Shunt Active Power Filter<bold> </bold>
Kale, Murat; Akar, Furkan; Karabacak, Murat (IEEE, 2018)Control of shunt active power filter (SAPF) requires a cascaded control structure as inner current closed loop followed by outer voltage control loop. The inner current control loop is responsible for tracking of a reference ... -
Fast Adaptive Robust Differentiator based Robust-Adaptive Control of Grid-Tied Inverters with a New L Filter Design Method
Kamal, Tariq; Karabacak, Murat; Kılıç, F.; Blaabjerg, Frede; Fernandez-Ramirez, Luis M. (MDPI AG, 2020)In this research, a new nonlinear and adaptive state feedback controller with a fast-adaptive robust differentiator is presented for grid-tied inverters. All parameters and external disturbances are taken as uncertain in ...