Gelişmiş Arama

Basit öğe kaydını göster

dc.contributor.authorCelik, Selda
dc.contributor.authorYilmaz, Feride Taskin
dc.contributor.authorAltas, Gulnaz
dc.date.accessioned2023-03-14T20:28:48Z
dc.date.available2023-03-14T20:28:48Z
dc.date.issued2022
dc.identifier.issn0962-1067
dc.identifier.issn1365-2702
dc.identifier.urihttps://doi.org/10.1111/jocn.16516
dc.identifier.urihttps://hdl.handle.net/20.500.14002/1426
dc.description.abstractAim and Objective This study was conducted to examine the development, characteristics, and risk factors of medical device-related pressure injury (MDRPI) in intensive care units (ICU). Background The number of individuals admitted to ICU increased in the last years all over the world. In parallel with this need, the frequency of the use of life-support and therapeutic medical devices in the ICU also increases. This situation may lead to the development of MDRPI in the ICU and an increase in its prevalence. Method The study, which was conducted observationally, prospectively and descriptively, included 302 patients who were hospitalised in an ICU within a year. The study was reported according to the STROBE Declaration. Results It was observed that MDRPI developed in 27.2% of the patients. It was found that MDRPI developed the most in the nose (26.8%) and mouth (15.9%) regions of the patients. It was determined that MDRPI was diagnosed in 28% of the patients within 3-5 days. It was determined that mostly orthopaedic devices (plaster, cervical collar, splint) (62.5%), fasteners (57.1%), non-invasive ventilation/oxygen masks (51.2%) caused the development of MDRPI. It was found that the number of medical devices used was higher, and the number of hospitalisation days in the ICU was also higher, and these factors explained 28.3% of the total variance in the development of MDRPI. Conclusion It was determined that MDRPI developed in approximately one of four patients in the ICU and that the numbers of medical devices and hospitalisation days were important determinant risk factors. Relevance to Clinical Practice The high rate of development of MDRPI is worrying in terms of nursing care quality. It is recommended that nurses recognise risk factors in order to prevent the development of MDRPI, evaluate the suitability, necessity, and safety of the devices to be used is located.en_US
dc.language.isoengen_US
dc.publisherWileyen_US
dc.relation.ispartofJournal Of Clinical Nursingen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectcareen_US
dc.subjectintensive careen_US
dc.subjectnursingen_US
dc.subjectpressure injuryen_US
dc.subjectrisk assessmenten_US
dc.subjectUlcersen_US
dc.subjectPreventionen_US
dc.subjectPrevalenceen_US
dc.titleMedical Device-Related Pressure injuries in adult intensive care unitsen_US
dc.typearticleen_US
dc.authoridaltaş, gülnaz/0000-0003-3678-628X
dc.authoridTaskin Yilmaz, Feride/0000-0003-0568-5902
dc.authoridCelik, Selda/0000-0003-4328-3189
dc.departmentBelirlenceken_US
dc.identifier.doi10.1111/jocn.16516
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorwosidaltaş, gülnaz/HOF-1315-2023
dc.identifier.wosWOS:000854606000001en_US
dc.identifier.scopus2-s2.0-85138116210en_US
dc.identifier.pmid36110029en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster